Goodwe inverter 5KW 6KW 8KW 10KW GW8kw ET

Goodwe three-phase hybrid inverter 5KW 6KW 8KW 10KW GW8kw ET

Price

24-hour hotline
+8618031297729

Parameter

Model

GW5K-ET

GW8K-ET

GW10K-ET

Battery Input Data

Battery Type

Li-Ion

Battery Voltage Range (V)

180~600

Max. Charging Current (A)

25

Max. Discharging Current (A)

25

Charging Strategy for Li-Ion Battery

Self-adaption to BMS

PV String Input Data

Max. DC Input Power (W)

6500

9600

13000

Max. DC Input Voltage (V)*1

1000

MPPT Range (V)*2

200~850

Start-up Voltage (V)

180

MPPT Range for Full Load (V)*3

240~850

Nominal DC Input Voltage (V)*4

620

Max. Input Current (A)

12.5/12.5

Max. Short Current (A)

15.2/15.2

No. of MPP Trackers

2

No. of Strings per MPP Tracker

1/1

AC Output Data (On-grid)

Nominal Apparent Power Output to Utility Grid (VA)

5000

8000

10000

Max. Apparent Power Output to Utility Grid (VA)*5

5000

8800

11000

Max. Apparent Power from Utility Grid(VA)

10000

15000

Nominal Output Voltage (V)

400/380, 3L/N/PE

Nominal Output Freqency (Hz)

50/60

Max. AC Current Output to Utility Grid (A)

8.5

13.5

16.5

Max. AC Current From Utility Grid (A)

32

40

45

Output Power Factor

~1(Adjustable from 0.8 leading to 0.8 lagging)

Output THDi (@Nominal Output)

<3%

AC Output Data (Back-up)

Max. Output Apparent Power (VA)

5000

8000

10000

Peak Output Apparent Power (VA)*6

10000, 60sec

16000, 60sec

16500, 60sec

Max. Output Current (A)

8.5

13.5

16.5

Nominal Output Voltage (V)

400/380

Nominal Output Freqency (Hz)

50/60

Output THDv (@Linear Load)

<3%

Efficiency

Max. Efficiency

98.0%

98.2%

Max. Battery to Load Efficiency

97.5%

Euro Efficiency

97.5%

MPPT Efficiency

99.9%

Protection

Anti-islanding Protection

Integrated

PV String Input Reverse Polarity Protection

Integrated

Insulation Resistor Detection

Integrated

Residual Current Monitoring Unit

Integrated

Output Over Current Protection

Integrated

Output Short Protection

Integrated

Battery Input Reverse Polarity Protection

Integrated

Output Over Voltage Protection

Integrated

General Data

Operating Temperature Range (°C)

-35~60

Relative Humidity

0~95%

Operating Altitude (m)

≤4000

Cooling

Natural Convection

Noise (dB)

<30

User Interface

LED & APP

Communication with BMS

RS485; CAN

Communication with Meter

RS485

Communication with EMS

RS485 (Insulated)

Communication with Portal

Wi-Fi

Weight (kg)

24

Size (Width*Height*Depth mm)

516*415*180

Mounting

Wall Bracket

Protection Degree

IP65

Standby Self Consumption (W)*7

<15

Topology

Grid Regulation

CEI 0-21; VDE4105-AR-N; VDE0126-1-1; EN50438; G83/2; G100

Safety Regulation

IEC62109-1&2

EMC

EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61000-4-16, EN61000-4-18, EN61000-4-29


Describe

Hc0cf13319f8a4a8ea125658775d7b8691.jpg

Hc75a033edd004e48a9ce26d7fc774413f.png

Ha4cd8618f2154966b16609830b43369dy.jpg

Hba635d9060994025ad92013486f03f5aT.jpg